FloWatch

62 posts

FloWatch banner
FloWatch

FloWatch

@watch_flo

Sprinkler Monitoring and Alarm Systems

England, United Kingdom Katılım Şubat 2019
171 Takip Edilen95 Takipçiler
FloWatch
FloWatch@watch_flo·
Lots of changes happening in the Domestic and Residential Sprinkler Market with the changes to BS9251 and building regulations. Contact FloWatch to organise a demonstration of how the FloWatch Sprinkler Monitoring system will help you to meet the new requirements!
English
0
0
0
0
FloWatch
FloWatch@watch_flo·
You know it makes sense Gary me old son..! If you are an M&E Consultant / Building Services Engineers specifying Domestic and Residential Sprinklers then get in contact today with FloWatch for your free 30 minute demo of FloWatch Sprinkler Monitoring Systems.
English
0
0
0
0
FloWatch
FloWatch@watch_flo·
A monitored isolation Valve is an isolation valve with an electrical switch fitted which shows if the valve is in the fully open position or not. We are seeing more of these specified on projects but what do you connect this switch to? Use the @Flowatch Sprinkler Monitoring
English
0
0
0
0
FloWatch
FloWatch@watch_flo·
other over who responsibility the wiring and alarms was. The Solution – FloWatch – Dedicated Fire Sprinkler Monitoring systems. Whether installed by an alarms contractor or Sprinkler Contractor or M&E Company, FloWatch will provide the guidance needed to ensure the system is
English
0
0
0
0
FloWatch
FloWatch@watch_flo·
an alarm from a monitored isolation valve should be distributed to alert responsible person that the system has been isolated on a residential or Domestic Fire Sprinkler System. So many times we have seen contractors get to an end of a project and everyone is looking at each
English
0
0
0
0
FloWatch
FloWatch@watch_flo·
Sprinkler Contractor: “I don’t touch the wiring” Sprinkler Contractor: “I’ve commissioned the system but no ones connected up the alarms so I’ll just note that on the certificate.” So often no one takes ownership of the Alarm signal from the flow switch or understanding how
English
0
0
0
0
FloWatch
FloWatch@watch_flo·
Contractor: “No one has wired between the Flow Switch and the IO module so we cant commission”
English
0
0
0
0
FloWatch
FloWatch@watch_flo·
How many times have you come across this on a job with residential sprinklers: Fire Alarm Contractor: “What’s the cause and effect of the flow switch Activation or Isolation Valve being closed?” Sprinkler Contractor: “I don’t know we just fit the flow switch.” Fire Alarm
English
0
0
0
0
FloWatch
FloWatch@watch_flo·
Trade Gaps occur often between fire alarm contractors and fire sprinkler contractors on residential sprinkler projects. Regardless of installation by either profession, FloWatch is the solution which bridges the gap between these two contractors when it comes to Domestic and
English
0
0
0
0
FloWatch
FloWatch@watch_flo·
FloWatch offer a Free Design Service on order placement for BS9251 Fire Sprinkler Monitoring systems. We Monitor Isolation Valves, Tanks and pumps to ensure the system is ready when required! If you don't know where to start, email us or give us a call to discuss your project
English
3
1
1
0
FloWatch
FloWatch@watch_flo·
project. We will detail which cable specification to use and how to terminate at all devices. We can offer advice on compatible Monitored Isolation Valves, tank level switches and flow switches. Contact us now at info@flowatch.co.uk or on 01737 481070 #fire #firesprinklers
English
0
0
0
0
FloWatch
FloWatch@watch_flo·
and let our sales team tailor a solution for your project. Once agreed this will be passed over to our competent design team to provide a fully coordinated design. We will provide layout drawings, schematics, wiring diagrams and commissioning points list specific to your
English
0
0
0
0
FloWatch
FloWatch@watch_flo·
Doing something new or different can be scary…… When Ways of working change it can be daunting adapting new methods… That’s what makes FloWatch special, we don’t just make clever monitoring systems, we provide the support and technical help from the start of a project
English
2
0
0
0