@CodysLab cody, your suit uses pure oxygen cylinders right? have you got a plan to counteract the oxygen toxicity from having oxygen above standard pressure? i ran into the issue myself and the only solution was to use compressed nitrogen-oxygen mix in an "open cycle" type configuration.
English

@Infinitech_Labs I've been thinking of try a mix with helium just for fun.
English

@Infinitech_Labs For short durations (eg leaks are insignificant) the nitrogen trapped in the suit doesn't get used up so I'm not actually in pure oxygen.
English

@CodysLab leaks WILL be a problem, every spacesuit is designed with leakage in mind. anything more than 15 or so minutes you'll end up in pure oxygen. also you need to be careful using mixed gas with a co2 scrubber, it will concentrate to dangerous levels in a closed cycle.(stay safe cody)