@syamkumarmd @ALFIEEP1 The first beat was the AP hiding with pre-ablation anxiety. As a German 🇩🇪 I’d say Argentina 🇦🇷 won 🏆 this AP ablation championship.
English
0
0
0
23
Syamkumar
Syamkumar@syamkumarmd·
@ALFIEEP1 Cool!, However, the first beat seen also shows no delta. How do you exclude intermittent spontaneous AP block here?
English
2
0
7
237
ALBERTO ALFIE
ALBERTO ALFIE@ALFIEEP1·
#WPW A new world record was set. QRS normalization in just 100 ms (0.1 sec) Location : left posteroseptal. Kent potential seen in bipolar and unipolar EGM. @hospitalposadas
ALBERTO ALFIE tweet media
English
1
3
35
2.1K
Andreas Müssigbrodt
Andreas Müssigbrodt@EPWaveDoc·
@veramasloo 😉 thank you. Don’t have the SN map on my phone. White dots: earliest activation during SR, checked for phrenic capture, then ablated earliest activation during AT. I did not think much about SN borders, as it’s a rather robust structure. Have you tried SN modulation in IST?
English
0
0
0
91
Vera Maslova
Vera Maslova@veramasloo·
@EPWaveDoc Great case, Andreas! Could you show the sinus node map? How have you defined the „borders“ of sinus node?
English
1
0
0
113
Andreas Müssigbrodt
Andreas Müssigbrodt@EPWaveDoc·
Interesting case of a difficult-to-induce ectopic atrial tachycardia in young woman presenting with palpitations. Successful ablation 5 mm from the sinus node #Epeeps
English
2
2
19
1.4K
Andreas Müssigbrodt
Andreas Müssigbrodt@EPWaveDoc·
@christophgelle1 Thank you! The white dots symbolize the sinus node from the sinus node activation map. There was no phrenic capture fortunately. And I used good old fashioned RF 😉 with very nice firing during the RF application and then cessation of ectopic activity.
Andreas Müssigbrodt tweet media
English
1
0
1
48
christoph geller
christoph geller@christophgelle1·
@EPWaveDoc Great! Did you use focal PFA? If the white dots are the phrenic nerve capture, it runs pretty close to.
English
1
0
1
43
Andreas Müssigbrodt
Andreas Müssigbrodt@EPWaveDoc·
@syamkumarmd Looks to me like two different (normal and accelerated) junctional rhythms. Genetics? Remember a 15 yo w flutter and binodal disease due to SCN5A mutation
English
2
0
5
389
Syamkumar
Syamkumar@syamkumarmd·
This boggles my mind! How to describe this rhythm best? Young patient with AF, post-ablation. #EPeeps
Syamkumar tweet media
English
4
1
29
3.3K
Roderick Tung
Roderick Tung@DrRoderickTung·
Yet another reason to avoid targeting the posterior fascicle with LBBaP. Posteromedial papillary muscle perforation with preserved electrical parameters: a novel complication of LBBaP heartrhythmcasereports.com/article/S2214-…
English
5
19
58
5.7K
Andreas Müssigbrodt
Andreas Müssigbrodt@EPWaveDoc·
54 y/o referred for epicardial VT ablation in DCM with frequent ICD therapies. EP study ➡️ concealed AP ➡️ Activation mapping during RV pacing. Early A w AP potential (?) near AV node. 10 s RF ⚡️ ➡️ junctional beats ➡️ AP gone. AV node alive. #Epeeps
Andreas Müssigbrodt tweet mediaAndreas Müssigbrodt tweet mediaAndreas Müssigbrodt tweet mediaAndreas Müssigbrodt tweet media
English
2
1
18
1.7K
Andreas Müssigbrodt ری ٹویٹ کیا
Alexandra R. D. Brigido
Alexandra R. D. Brigido@alexandra_regia·
One more #anatomylab with CTI-dependent #atrialflutter #ablation. It shows TV (Tricuspid valve), RA (Right atrium), CTI (Cavo-tricuspid isthmus) and IVC (Inferior vena cava). Pay attention to structures that can difficult to create a closed ICT line! #eplovers #epfellow
English
2
68
194
0
Andreas Müssigbrodt
Andreas Müssigbrodt@EPWaveDoc·
@GauravGad I am afraid I personally cannot help you. Did you contact the physician who has implanted your pacemaker?
English
0
0
0
7
Gaurav Gadhoke
Gaurav Gadhoke@GauravGad·
I have a medtronic packemaker. I just received a new pacing device that apparently works with smart phones or tablet. I have tried is all but it does not send the transmission. i have been calling customer care and I have spoken to seniors as well as junior team but they are unable to get to the solution. I need the bosses to intervene in this matter
English
1
0
0
8
Andreas Müssigbrodt
Andreas Müssigbrodt@EPWaveDoc·
Tonight: rendezvous between an Abbott Aveir delivery sheath (30 cm, jugular access) and a Medtronic Micra leadless pacemaker. #Epeeps #Cardiology
Andreas Müssigbrodt tweet mediaAndreas Müssigbrodt tweet media
English
1
0
1
389
Andreas Müssigbrodt
Andreas Müssigbrodt@EPWaveDoc·
@syamkumarmd Important concern! Limited space for discussion. It seems like irrigation rate during ablation plays a role in white spot occurence. Therefore we do all ablations w Varipulse w 30 ml/min. No clinical neurological problems observed so far.
English
0
0
2
228
Syamkumar
Syamkumar@syamkumarmd·
@EPWaveDoc What is your experience with the concerns regarding brain lesions?
English
1
0
1
381
Andreas Müssigbrodt
Andreas Müssigbrodt@EPWaveDoc·
Single-shot #PFA has downsides, including limited individualized #ablation strategies & less intellectual/manual challenge (nostalgia?) compared w #RFA. However, this #Varipulse #AF #ablation was very convenient, safe & rapid. W Veauthyelau Saint-Joy & Arnaud Rousselet #Epeeps
Andreas Müssigbrodt tweet media
English
2
0
11
1.9K
Milan Koštek
Milan Koštek@KostekMilan·
@PurumittalDr @EkgHacks @ecgchallenge @EPeeps_Bot Progressive shortening is characteristic for decremental Wenckebach conduction pattern since increments in conduction are progressively smaller and that's why RR intervals are accelerating. AT Ps 🟡 go from the latter half of T waves progressively closer to QRS until blocked.
Milan Koštek tweet media
English
5
5
35
2.7K
Andreas Müssigbrodt
Andreas Müssigbrodt@EPWaveDoc·
@KostekMilan @Frances98392343 Dear Prof Kostek, the AVN was mistakenly ablated in 2014 in another center probably by ablation close to the fast pathway. The pacemaker’s lead is in the RVOT. Axis is uncommon indeed. The fast conducting AS AP was ablated after gen change in our center to reduce risk of SCA.
English
1
0
2
188
Milan Koštek
Milan Koštek@KostekMilan·
@EPWaveDoc @Frances98392343 Dear professor, @EPWaveDoc . The pic shows complete AV block. Was this AP burned totally and then PM was implanted? Where's the pacing lead placed with this LBBB morphology and the right axis deviation? What was the definitive solution? Thank you.
English
1
0
1
247
Andreas Müssigbrodt
Andreas Müssigbrodt@EPWaveDoc·
#Epeeps: Ablate this AP? 51-yo asymptomatic woman, prior complicated AP ablation → #pacemaker. ECG: max pre-excitation in SR. EPS: no AVN conduction, SPPCL 240 ms, constant pre-excitation in AF. Slanted AS-AP. First RF 🔥 → CHB (expected). #MapMoreBurnLess
Andreas Müssigbrodt tweet mediaAndreas Müssigbrodt tweet mediaAndreas Müssigbrodt tweet media
English
1
4
18